MATS-2010H Hysteresis loop
tracer
Automatic measurement on saturation hysteresis loop and magnetic
characteristic parameters of generally permanent-magnet material such as
Ferrite, Rubber & Plastic Magnet and AlNiCo, Js, Br, HcB, HcJ, (BH)max and
μrec.
·Automatic
measurement on demagnetization curve and magnetic characteristic parameters of
rare earth permanent-magnet materials such as NdFeB and SmCo, etc. At the second
quadrant: Br, HcB, HcJ, Hk (H90) and (BH)max.
·Test
sample shapes: toroid, round cake, square, tile and other irregular shapes.
·Adopt
B coil + Fluxmeter to measure magnetic induction, zero shift of
integrator can be self-corrected through software.
·Adopt
J coil + fluxmeter to measure magnetical polarization, remnant coil area of J
coil can be automatically compensated through software.
·Magnetic
field intensity can be measured with Hall magnetometer, nonlinear error of hall
probe can be corrected through software, within 0 ~ 2.4 T range, nonlinear error
can be controlled within ±0.2%.
·Adopt
H coil + fluxmeter to measure magnetic field intensity, Hall magnetometer only
used to indicate zero point of magnetic field so as to thoroughly eliminate
nonlinear error of hall probe.
·Optimal
range of field voltage, fluxmeter and magnetometer can be automatically set up.
·Magnetization,
testing and demagnetization of general permanent magnetic sample can be
completed at one time, time set up 20 seconds ~ 60 seconds.
·Rare
earth permanent magnetic samples need saturation magnetizing before testing,
testing time 60 seconds ~ 120 seconds.
·The
sample after testing can be in a state of demagnetization or magnetizing, freely
selected buy users.
·Select
heating head and temperature controller to detect magnetic characteristics of
Ferrite, AlNiCo and rare earth material under high temperature (maximam
220°C).
·Select
shoe jig for direct measurement on magnetic shoe.
System Specifications
Test AlNiCo standard sample, measuring error on entire magnetic hysteresis
cycle estimated: B: 1%, H: 1%
| Parameters
measured |
Br (%) |
HcB (%) |
HcJ (%) |
(BH)max (%) |
| Uncertainty (k = 2) |
1 |
1 |
1 |
2 |
| Repeatability (constant
temperature) |
± 0.3 |
± 0.3 |
± 0.3 |
± 1 |
Instrument Specifications
| TPS-2000H Test Power Supply |
|
DCT130
Electromagnet |
Output
Voltage: 0 ~ ±100 V Output Current: ±20 A
(maximum value) Stability: superior to
0.05% Output protection: overvoltage,
overflowing, short-circuits protection |
Head Diameter: 130
mm Head Spacing: 0 ~ 50 mm (continual
adjustable) Maximal Magnetic Field: 1.5 T (head
spacing 10 mm, coil current 20 A) |
| TPS-2100H Test Power Supply |
DCT150
Electromagnet |
Supply
Voltage: single phase, 220V 50Hz Output Voltage: 0 ~
±120 V Output Current: ±30 A (maximum
value) Output protection: overvoltage, overflowing,
short-circuits protection |
Head
Diameter: 150 mm shrink to 80 mm Head Spacing:
0 ~ 50 mm (continual adjustable) Maximal
Magnetic Field: 2.4 T (head spacing 10 mm,coil current 30 A) |
| TPS-2200H Test Power Supply |
DCT200
Electromagnet |
Supply
Voltage: single phase, 220V 50Hz Output Voltage: 0 ~
±200 V Output Current: ±60 A (maximum
value) Output protection: overvoltage, overflowing,
short-circuits protection |
Head Diameter: 200 mm shrink to 80
mm Head Spacing: 0 ~ 50 mm (continual
adjustable) Maximal Magnetic Field: 2.7 T (head
spacing 10 mm, coil current 60 A) |
| TPS-2300H Test Power Supply |
DCT250
Electromagnet |
Supply
Voltage: three phase, 380V 50Hz Output Voltage: 0 ~
±300 V Output Current: ±60 A (maximum
value) Output protection: overvoltage, overflowing,
short-circuits protection |
Head Diameter: 250 mm shrink to 80
mm Head Spacing: 0 ~ 80 mm (continual
adjustable) Maximal Magnetic Field: 2.8 T (head
spacing 10 mm, coil current 60 A) |
| LZ-210B Fluxmeter |
|
PC6023
A/D D/A card |
Range:
2.5, 5, 10, 20 mWb Full Range Precision: 0.5%
Zero Shift: 2 μWb / 30 seconds (2.5 mWb) |
A/D Conversion: 12 bits, 32
channels Conversion Time: < 10
μs Conversion Accuracy: 0.1% (full
range) D/A Conversion: 12 bits, 2
channels Conversion Accuracy: 0.1% (full
range) |
| LZ-210H
Magnetometer |
PC6616 A/D D/A
card |
Range: 0.5, 1,
1.5, 3 T Full Range Precision: 0.5%
Non-Linearity: ±0.2% (software correction) |
A/D
Conversion: 16 bits, 8 channels differential input
Conversion Time: < 10 μs Conversion Accuracy:
0.02% (full range) D/A Conversion: 12 bits, 2
channels Conversion Accuracy: 0.1% (full
range) |
Leave a message